PRESSURE TRANSMITTER

PS98i SUBMERSIBLE PRESSURE TRANSMITTER

 

•  Industry standard, two-wire, 4-20mA configuration

•  Small diameter

•  Improved noise immunity

•  End cone option

•  316 stainless steel, Viton® and Teflon® construction

•  Polyethylene, polyurethane and FEP Teflon® cable options

PS98i Installation Options

 

 

DESCRIPTION

The patented PS98i submersible pressure transmitter represents the latest in state-of-the-art level measurement technology. Building on years of successful experience, this industry standard two-wire, 4-20 mA device offers improved noise immunity, thermal performance and transient protection. In addition to reverse polarity protection, under-current and over-current limitation is featured on the transmitter channel.  The updated cable harness design reduces the probability of leakage and protects the cable jacket from damage by providing double-sealing; 316 stainless steel, Viton® and Teflon® construction increases corrosion resistance. The transmitter’s standard end cone is a 1/4” NPT inlet which allows for increased application use, easy hookup and field calibration. The modular-designed PS98i may be easily factory serviced and repaired.

OPERATION

The PS98i pressure transmitter is powered by a datalogger or control system. The internal electronic circuit controls the amount of current flowing through the loop based on the signal from the internal pressure sensor. An above-surface probe will draw 4 mA and once submerged, the current flow increases linearly with pressure (or depth). At full-scale pressure (depth), the transmitter will draw 20 mA. A data acquisition/or control system then measures this current and computes the pressure or level.

APPLICATIONS

Due to its rugged construction and proven reliability, the PS98i is used successfully to monitor groundwater, well, tank and tidal levels, as well asfor pump testing and flow monitoring.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIMENSIONS AND SPECIFICATIONS

HOW TO ORDER

• Choose the transmitter with the

required pressure range.

• Determine cable type and specify length.

• Contact DSI for a full list of accessories.

PS98i SUBMERSIBLE PRESSURE

TRANSMITTER RANGES

Part #

Pressure

Range

Part #

Pressure

Range

5773C360

5 PSIG

5773C365

50 PSIA

5773C361

15 PSIG

5773C366

100 PSIG

5773C362

30 PSIG

5773C367

100 PSIA

5773C363

30 PSIA

5773C368

300 PSIG

5773C364

50 PSIG

5773C369

300 PSIA

 

PS98i CABLE OPTIONS

Part #

Description

5776E540  

Vented PU INW Cable

5776E543

Vented FEP Cable

5776E542

Vented HDPE INW Cable

 

PS98i MISCELLANEOUS OPTIONS

Part #

DESCRIPTION

5776E405

End Cone (Replaces 1/4" FNPT Adapter)

MECHANICAL

Transmitter

Body Material

316 Stainless Steel

Wire Seal Materials

Viton® and Teflon®

Desiccant

High & Standard capacity packs

Terminating Connector

Available

Weight

.75lbs.

Cable

OD

0.28” max.

Break Strength

138 lbs.

Maximum Length

2000 feet

Weight

4 lbs. per 100 feet

 

ELECTRICAL

Pressure

Transmitter Voltsge

9-24 VDC 100ms Warmup

Static Accuracy

(B.F.S.L 25° C)*

±0.25% FSO (max.)

±0.1% FSO (typical)

0.1% Available on Request

Thermal Error

(0-50 C Reference 25° C)

±2.0% FSO (max.)

±0.8% FSO (typical)

Maximum

Zero Offset at 25° C

±0.5% FSO

Sensitivity Accuracy @ 25° C

±0.25% FSO (max.)

±0.125% FSO (typical)

Over Range  Protection

2x (except 300 PSIA)

Compensated Temperature Range

0 - 50° C

Operating Temperature Range -5° C to 70° C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DRILLERS SERVICE, INC.                      HICKORY, NC USA                    800-334-2308,  EXT. 230