Stainless Steel Screen
Specifications & Intake
![]()
Small Diameter "Rod Base" Well Screens
|
Open Area - Sq. In./ Ft. Screen Collapse Strength (PSI) 4 Screen Slot Size (Thousandths of an inch)
|
|
Environmental & Water Well "Heavy Weight Construction" - 304 & 316 Stainless Steel |
|
Size |
OD (in) |
Clear ID (in) |
Wire Width (in) |
Screen Wt/Ft * (Lb) |
Max Depth (Ft) |
Tensile Strength (Lb) 1 |
Hang Weightt (Lb) 2 |
Column Strength (Lb) 3 |
|
1 1/4" |
1.7 |
1.1 |
0.060 |
1.8 |
1,000 |
4,200 |
2,100 |
3,100 |
|
2"P ** |
2.5 |
1.9 |
0.060 |
1.9 |
1,000 |
2,000 |
1,000 |
1,500 |
|
2"P/3"T |
2.6 |
2.0 |
0.060 |
2.2 |
1,000 |
3,400 |
1,700 |
2,600 |
|
2 1/2"P |
3.0 |
2.4 |
0.060 |
2.6 |
1,000 |
4,200 |
2,100 |
3,100 |
|
3"P ** |
3.6 |
2.9 |
0.060 |
2.9 |
1,000 |
4,200 |
2,100 |
3,100 |
|
3"P/4"T |
3.7 |
3.1 |
0.060 |
3.0 |
1,000 |
4,200 |
2,100 |
3,100 |
|
4"P |
4.6 |
4.0 |
0.060 |
3.7 |
600 |
4,800 |
2,400 |
3,700 |
|
4"P/5"T |
4.7 |
4.1 |
0.060 |
3.8 |
600 |
4,800 |
2,400 |
3,700 |
|
5"P/6"T |
5.6 |
5.0 |
0.060 |
4.5 |
400 |
5,600 |
2,800 |
4,200 |
|
Environmental & Water Well "Light Weight Construction" - 304 & 316 Stainless Steel |
|
Size |
OD (in) |
Clear ID (in) |
Wire Width (in) |
Screen Wt/Ft (Lb) |
Max Depth (Ft) |
Tensile Strength (Lb) 1 |
Hang Weightt (Lb) 2 |
Column Strength (Lb) 3 |
|
1 1/4" |
1.7 |
1.1 |
0.089 |
1.5 |
600 |
4,200 |
2,100 |
3,100 |
|
2"P ** |
2.4 |
1.9 |
0.060 |
1.9 |
600 |
2,000 |
1,000 |
1,500 |
|
2"P/3"T |
2.5 |
2.0 |
0.060 |
2.2 |
600 |
3,400 |
1,700 |
2,600 |
|
2 1/2"P |
3.0 |
2.4 |
0.060 |
2.6 |
600 |
4,200 |
2,100 |
3,100 |
|
3"P ** |
3.5 |
2.9 |
0.060 |
2.9 |
600 |
4,200 |
2,100 |
3,100 |
|
3"P/4"T |
3.7 |
3.1 |
0.060 |
3.0 |
600 |
4,200 |
2,100 |
3,100 |
|
4"P |
4.5 |
4.0 |
0.060 |
3.7 |
250 |
4,800 |
2,400 |
3,700 |
|
4"P/5"T |
4.7 |
4.1 |
0.060 |
3.8 |
250 |
4,800 |
2,400 |
3,700 |
|
5"P/6"T |
5.6 |
5.0 |
0.060 |
4.5 |
100 |
5,600 |
2,800 |
4,200 |
|
Open Area - Sq. In./ Ft. Screen Collapse Strength (PSI) 4 Screen Slot Size (Thousandths of an inch)
|
The "Heavy Weight Screen will be quoted unless soecified other wise.
Transmitting Capicity in gpm / ft. Screen = Open Area X .31
* Weight based on 10 slot construction (no fittings)
(1) Tensile and Column strength includes 30% safety factor.
(2) Hang weight is 50% of calculated Tensile strength.
(3) Column strength is based on 5 ft. Screen length.
(4) Calculated Collapse values - No safety factor.
(**) Alternate Construction for Environmental Applications
(P) Pipe Size
(T) Telescope Size
DRILLERS SERVICE, INC. HICKORY, NC USA 800-334-2308, EXT. 230