SHUR-SEAL™  SCREENS  

                                               INTAKE  AREA

 

APPROXIMATE MAXIMUM FLOW CAPACITY

PVC Schedule 40                                                                            ¼" (.250) spacing between slots

Screen Diameter

Slot Size

Intake Area  

Sq. / ft.

Maximum Flow Capacity gpm / ft.

 

.010

.215

.067

1/2"

.016

.344

.107

 

.020

.430

.133

 

.010

.301

.093

3/4"

.016

.482

.149

 

.020

.602

.187

 

.010

.516

.160

1"

.016

.826

.256

 

.020

1.032

.320

 

.010

.860

.267

1¼"

.016

1.376

.427

 

.020

1.720

.533

 

.010

1.075

.333

.016

1.720

.533

 

.020

2.150

.667

 

.010

2.060

.639

2"

.016

2.840

.880

 

.020

3.930

1.218

 

.010

3.430

1.063

4"

.016

5.500

1.705

 

.020

6.560

2.034

 

.010

4.810

4.911

6"

.016

7.310

2.266

 

.020

9.180

2.846

 

.010

5.690

1.764

8"

.016

--------

 

 

.020

10.860

3.367

        DRILLERS SERVICES, INC.    Hickory, North Carolina USA       800-334-2308, ext. 230 