Johnson PVC Vee - Wire Screen

Size   

Nominal

Clear ID

Weight

Tensile

Hang

Collapse  Strength (psi) (3)

(Inches)

OD

(Inches)

per ft.

Strength

Weight

Slot Size

 

(Inches)

(1)

(lbs)

(lbs) (2)

(lbs)(4)

0.006

0.010

0.020

0.030

0.040

0.050

1 ¼" PS

1.66

1.12

0.07

780

195

269

261

242

226

212

199

1 ½" PS

1.90

1.41

0.08

1,245

310

181

175

163

152

143

134

2" PS/3T

2.37

1.88

0.08

1,325

330

95

92

85

79

74

70

2" PS *

2.60

2.00

0.90

1,325

330

72

70

65

61

57

54

3" PS

3.50

2.89

1.50

1,820

455

169

164

154

145

137

130

4" Special

4.50

3.81

1.70

2,100

525

81

78

74

69

65

62

4" PS

4.62

4.00

1.80

2,100

525

75

73

68

64

60

57

5" PS

5.56

4.81

2.50

3,920

980

73

71

67

63

60

57

6" PS

6.61

5.75

3.70

4,600

1,150

73

72

68

65

62

59

8" PS

8.62

7.50

4.60

5,500

1,375

60

59

55

52

49

46

 

 

For shallow wells, sonic-welded PVC screens have continuous slot design producing

more open area for a given slot size than any other non-metallic screen available. PVC

resists corrosion and may be treated repeatedly with acid to remove encrustations.  

Screens to 6-inch diameter are made with standard rod base .8-inch diameter screens

have channel-rod base for enhanced strength.

 

 FLOW RATES

 

 

Screen Slot Size

 

.006

.010

.020

.030

.040

.050

Size   

Open Area

Max.  Flow

Open Area

Max.  Flow

Open Area

Max.  Flow

Open Area

Max.  Flow

Open Area

Max.  Flow

Open Area

Max.  Flow

(Inches)

(sq. in. / ft.)

(gpm / ft.)

(sq. in. / ft.)

(gpm / ft.)

(sq. in. / ft.)

(gpm / ft.)

(sq. in. / ft.)

(gpm / ft.)

(sq. in. / ft.)

(gpm / ft.)

(sq. in. / ft.)

(gpm / ft.)

1 ¼" PS

3.0

0.9

4.8

1.5

8.9

2.8

12.5

3.9

15.6

4.8

18.4

5.7

1 ½" PS

3.4

1.1

5.5

1.7

10.2

3.2

14.3

4.4

17.9

5.5

21.0

6.5

2" PS/3T

4.2

1.3

6.9

2.1

12.8

4.0

17.8

5.5

22.3

6.9

26.3

8.2

2" PS *

4.6

1.4

7.5

2.3

14.0

4.3

19.6

6.1

24.5

7.6

28.8

8.9

3" PS

5.4

1.7

8.8

2.7

16.5

5.1

23.3

7.2

29.3

9.1

34.7

10.8

4" Special

6.9

2.1

11.3

3.5

21.2

6.6

30.0

9.3

37.7

11.7

44.6

13.8

4" PS

7.1

2.2

11.6

3.6

21.8

6.8

30.7

9.5

38.7

12.0

45.8

14.2

5" PS

8.1

2.5

13.1

4.1

24.6

7.6

34.9

10.8

44.1

13.7

52.4

16.2

6" PS

8.0

2.5

13.1

4.1

24.9

7.7

35.6

11.0

45.3

14.0

54.2

16.8

8" PS

13.3

4.1

21.6

6.7

40.6

12.6

57.3

17.8

72.2

22.4

85.5

26.5

 

 

 

 

 

 

 

 

 

 

 

 

 

VEE - WIRE SPECIFICATIONS

 

 

        DRILLERS SERVICE, INC.                   HICKORY, NC USA                  800-334-2308,  EXT. 230

                                 [About Us][Products][News][Trade Shows][Contact Us]

 

 

 

 

(1)  Clear ID's are minimum inside diameters.  (2)  Tensile values in bold type are based on support rod ares.  Other values are based on flush thread test values.  (3)  Collapse strengths are calculated values.  No safety factor included.  (4)  Hang weights are the maximum combined weight of riser and screen from the top of the screen.  