Johnson PVC Vee - Wire Screen
|
Size |
Nominal |
Clear ID |
Weight |
Tensile |
Hang |
Collapse Strength (psi) (3) |
|||||
|
(Inches) |
OD |
(Inches) |
per ft. |
Strength |
Weight |
Slot Size |
|||||
|
|
(Inches) |
(1) |
(lbs) |
(lbs) (2) |
(lbs)(4) |
0.006 |
0.010 |
0.020 |
0.030 |
0.040 |
0.050 |
|
1 ¼" PS |
1.66 |
1.12 |
0.07 |
780 |
195 |
269 |
261 |
242 |
226 |
212 |
199 |
|
1 ½" PS |
1.90 |
1.41 |
0.08 |
1,245 |
310 |
181 |
175 |
163 |
152 |
143 |
134 |
|
2" PS/3T |
2.37 |
1.88 |
0.08 |
1,325 |
330 |
95 |
92 |
85 |
79 |
74 |
70 |
|
2" PS * |
2.60 |
2.00 |
0.90 |
1,325 |
330 |
72 |
70 |
65 |
61 |
57 |
54 |
|
3" PS |
3.50 |
2.89 |
1.50 |
1,820 |
455 |
169 |
164 |
154 |
145 |
137 |
130 |
|
4" Special |
4.50 |
3.81 |
1.70 |
2,100 |
525 |
81 |
78 |
74 |
69 |
65 |
62 |
|
4" PS |
4.62 |
4.00 |
1.80 |
2,100 |
525 |
75 |
73 |
68 |
64 |
60 |
57 |
|
5" PS |
5.56 |
4.81 |
2.50 |
3,920 |
980 |
73 |
71 |
67 |
63 |
60 |
57 |
|
6" PS |
6.61 |
5.75 |
3.70 |
4,600 |
1,150 |
73 |
72 |
68 |
65 |
62 |
59 |
|
8" PS |
8.62 |
7.50 |
4.60 |
5,500 |
1,375 |
60 |
59 |
55 |
52 |
49 |
46 |

For shallow wells, sonic-welded PVC screens have continuous slot design producing
more open area for a given slot size than any other non-metallic screen available. PVC
resists corrosion and may be treated repeatedly with acid to remove encrustations.
Screens to 6-inch diameter are made with standard rod base .8-inch diameter screens
have channel-rod base for enhanced strength.
FLOW RATES
|
|
Screen Slot Size |
|||||||||||
|
|
.006 |
.010 |
.020 |
.030 |
.040 |
.050 |
||||||
|
Size |
Open Area |
Max. Flow |
Open Area |
Max. Flow |
Open Area |
Max. Flow |
Open Area |
Max. Flow |
Open Area |
Max. Flow |
Open Area |
Max. Flow |
|
(Inches) |
(sq. in. / ft.) |
(gpm / ft.) |
(sq. in. / ft.) |
(gpm / ft.) |
(sq. in. / ft.) |
(gpm / ft.) |
(sq. in. / ft.) |
(gpm / ft.) |
(sq. in. / ft.) |
(gpm / ft.) |
(sq. in. / ft.) |
(gpm / ft.) |
|
1 ¼" PS |
3.0 |
0.9 |
4.8 |
1.5 |
8.9 |
2.8 |
12.5 |
3.9 |
15.6 |
4.8 |
18.4 |
5.7 |
|
1 ½" PS |
3.4 |
1.1 |
5.5 |
1.7 |
10.2 |
3.2 |
14.3 |
4.4 |
17.9 |
5.5 |
21.0 |
6.5 |
|
2" PS/3T |
4.2 |
1.3 |
6.9 |
2.1 |
12.8 |
4.0 |
17.8 |
5.5 |
22.3 |
6.9 |
26.3 |
8.2 |
|
2" PS * |
4.6 |
1.4 |
7.5 |
2.3 |
14.0 |
4.3 |
19.6 |
6.1 |
24.5 |
7.6 |
28.8 |
8.9 |
|
3" PS |
5.4 |
1.7 |
8.8 |
2.7 |
16.5 |
5.1 |
23.3 |
7.2 |
29.3 |
9.1 |
34.7 |
10.8 |
|
4" Special |
6.9 |
2.1 |
11.3 |
3.5 |
21.2 |
6.6 |
30.0 |
9.3 |
37.7 |
11.7 |
44.6 |
13.8 |
|
4" PS |
7.1 |
2.2 |
11.6 |
3.6 |
21.8 |
6.8 |
30.7 |
9.5 |
38.7 |
12.0 |
45.8 |
14.2 |
|
5" PS |
8.1 |
2.5 |
13.1 |
4.1 |
24.6 |
7.6 |
34.9 |
10.8 |
44.1 |
13.7 |
52.4 |
16.2 |
|
6" PS |
8.0 |
2.5 |
13.1 |
4.1 |
24.9 |
7.7 |
35.6 |
11.0 |
45.3 |
14.0 |
54.2 |
16.8 |
|
8" PS |
13.3 |
4.1 |
21.6 |
6.7 |
40.6 |
12.6 |
57.3 |
17.8 |
72.2 |
22.4 |
85.5 |
26.5 |
VEE - WIRE SPECIFICATIONS
DRILLERS SERVICE, INC. HICKORY, NC USA 800-334-2308, EXT. 230
(1) Clear ID's are minimum inside diameters. (2) Tensile values in bold type are based on support rod ares. Other values are based on flush thread test values. (3) Collapse strengths are calculated values. No safety factor included. (4) Hang weights are the maximum combined weight of riser and screen from the top of the screen.
All strength properties are based on 72° F temperature. * Alternate construction for environmental applications.